46. DESIGN OF STEEL PYRAMID USING FLUID VISCOUS DAMPERS WITH MOMENT FRAMES

The Eleven story 450,000 ft2 pyramid shaped office building described in this article was one of the first new buildings in the United States to use Seismic Dampers. This National Headquarters for a financial institution is located in West Sacramento, CA. The basic lateral force resisting system of the building consists of steel moment frames. In addition, approximately 15% of critical damping was provided using Fluid Viscous Dampers (FVD) in order to reduce displacement and acceleration. The steel moment frames were designed to remain well below the yield strength, and the story drift ratio was limited to 0.005 to protect the welded moment connections for the Design Basis Earthquake (DBE). Earthquake performance, cost effectiveness, and architectural requirements were the primary concerns in designing this building.