RESOURCES

Seismic Applications

White Paper

87. Fluid Dampers for Seismic Protection of Woodframe Structures

In the recent past a large number of steel framed buildings have used supplemental energy dissipation systems to provide seismic protection. However, the application of such systems to wood frame structures has been essentially non-existent except for a limited number of experimental laboratory studies. This paper presents a numerical study of the application of fluid dampers for seismic protection of wood framed structures. Such dampers dissipate energy via orificing of a fluid. The seismic response of a wood framed shear wall with and without dampers is evaluated via nonlinear finite element analyses. The results of the analyses demonstrate that the dampers are capable of dissipating a large portion of the seismic input energy while simultaneously relieving the inelastic energy dissipation demand on the shear wall.

White Paper

86. Base Isolation and Supplemental Damping Systems for Seismic Protection of Wood Structures

This paper provides a literature review on the application of base isolation and supplemental damping systems for seismic protection of wood structures. The review reveals that both elastomeric bearings and sliding bearings have been considered for implementation within base isolation systems of wood framed buildings. In addition, friction dampers, viscoelastic dampers, hysteretic dampers, and fluid viscous dampers have been considered for implementation within the framing of wood buildings. Although there are a number of impediments to the widespread implementation of such advanced seismic protection systems, the reviewed literature clearly demonstrates that advanced seismic protection systems offer promise for enabling light framed wood structures to resist major earthquakes with minimal damage.

White Paper

82. Full-Scale Shake Table Tests of 5-Story Steel Building with Viscous Damping

Realistic simulations of earthquake responses were conducted in March 2009 for a full-scale 5-story building specimens with dampers using the E-Defense, the world’s largest three-dimensional shake table. The building was tested repeatedly, inserting and replacing each of 4 damper types, steel damper, oil damper, viscous damper and viscoelastic damper. This paper discusses the test method and test results as well as details of the 5-story building specimen. Performance improvement by the dampers is addressed for moderately tall buildings that constitute a major portion of the building stock.

White Paper

81. Applicability of Seismic Protective Systems to High-Tech Industrial Structures

This paper summarizes a feasibility study for implementing seismic protective systems into high tech industrial structures in which costly vibration sensitive facilities are housed. Micro-vibration control of an IC fab is essential for optimum yield of reliable chip products. This paper describes the micro vibration analysis and measurement of a test structure before and after the incorporation of Seismic Protective systems. Based on the study, it is found that the incorporation of viscous dampers both enhances seismic safety and also minimizes the micro vibration of the structure. Viscous damper seismic isolation is the most promising method to achieve the “fully operational” seismic performance level of an IC fab.

Case Study

75. Structural Control Using Hybrid Spring-Damper Isolator with Integral Gapping Function

The spring-damper isolators described in this paper were used on the world’s largest cable stayed bridge – the Sutong Bridge over China’s Yangtze River, completed in 2008. The Sutong Bridge is located north of Shanghai in China’s Jiangsu Province at a site where catastrophic earthquakes, typhoons, and ship impact are key design issues. The total length of the bridge is 4.7 miles, with a .67 mile long center span. The tall support towers of this bridge and the long support cables create long period motions along the primary axis of the bridge. The need to accommodate thermal expansion and contraction of the deck axially means that extensive motion can occur in this direction. The configuration of the bridge permits large axial motion of the suspended deck during earthquakes, typhoons, and synchronized truck/car braking loads such as would occur during a mass vehicular accident on the bridge. During dynamic earthquake loading, the long period of the suspended deck provides inherent isolation, albeit essentially undamped. Analysis indicated that added viscous damping would reduce deck motions substantially. During other events like typhoons and vehicle loading, analysis determined that the most cost-effective solution was to incorporate a snubbing type spring element that would only engage (become active) when the damper was approaching its end of travel in either extension or compression. The spring-dampers on this bridge have only damping forces for roughly 85% of the available displacement from the neutral (center of travel) position. Beyond this travel the spring element engage and a combined response of spring plus damper forces results. Essentially, the spring elements are “gapped” through all but approximately the last 15% of the damper stroke in either direction.

White Paper

71. Seismic Protection with Fluid Viscous Dampers for the Torre Mayor, a 57-Story Office Tower in Mexico City, Mexico

The new 57 story Torre Mayor Building is the now the dominant structure in the Mexico City skyline. It is also the first tall building to utilize large Fluid Viscous Dampers as a primary means of seismic energy dissipation. A total of 98 dampers are used, including 24 large dampers, each rated at 570 tonnes of output force, located in the long walls of the building. The short walls utilize 74 smaller dampers, each rated at 280 tonnes of output force. The damping technology successfully implemented for Torre Mayor is now being used on five other tall buildings, including three in the USA, and two in Japan.

Case Study

70. Seismic Rehabilitation of Historic Concrete Structure with Fluid Visco-Elastic Dampers

This paper presents the nonlinear seismic analysis, development, and implementation of an innovative seismic retrofit strategy for a six story nonductile reinforced concrete 145,000 square foot historic building. Dynamic and nonlinear static analytical results verified that the building had a weak soft story with inadequate post yield capacity and large torsional response. Hotel Stockton, in Stockton, CA, is also torsionally irregular. The analysis indicated that the existing building was not seismically adequate to withstand anticipated lateral forces generated by earthquake excitations at the site. A “collapse prevention” performance upgrade for a 475-year return event was developed. Nonlinear fluid viscous dampers were placed at the first story level to reduce the seismic demand and obtain a more uniform response. Viscoelastic fluid viscous dampers were strategically placed at one side of the building to reduce the torsional irregularity of the building. This cost effective retrofit significantly improved the seismic performance of the building.

Case Study

67. U.S. Design of Structures with Damping Systems

This paper presents an earthquake design procedure and a case study of the Vacaville Police Headquarters. The design goal for this essential facility was to provide immediate occupancy after a 475-year return seismic event. The project also required construction cost within typical code conforming buildings. A combination of Special Moment Resisting Frames (SMRF) and Fluid Viscous Dampers (FVDs) was used as the lateral force resistance system. This system, as described by Gimmel, Lindorfer, and Miyamoto, (2002) results in cost efficiency and superior seismic performance. The 2000 NEHRP (FEMA, 2000) guideline was used to design the project, since it is considered to be a state-of-art procedure for seismic damping devices. This project was the first structure in the United States to use this advanced procedure.

White Paper

65. Viscous Damper Development and Future Trends

Viscous dampers can protect structures against wind excitation, blast and earthquakes. Viscous damper technology originated with military and aerospace applications. Approximately 20 years ago it was found that the same fluid viscous dampers that protect missiles against nuclear attack and guard submarines against near miss underwater explosions could also protect buildings, bridges and other structures from destructive shock and vibration. This paper describes fluid damper technology, analysis considerations, installation methods and development work in progress.