Resources

Technical Papers

57. Structural Control of Dynamic Blast Loading Using Fluid Viscous Dampers

This paper evaluates the effectiveness of Fluid Viscous Dampers to reduce blast loading responses in steel buildings. The paper addresses the following issues: (1) development of a blast loading time history from a 3,000 pound explosive charge, (2) characteristics and historical applications of fluid Viscous Dampers for blast and weapon effects, and (3) blast effects and performance comparisons of a conventional steel building frame with and without dampers, and a conventional concrete shear wall building. Simulation results indicate that Fluid Viscous Dampers provide a cost effective way to greatly improve the performance of steel building frames under blast loading.

Share This Post

More To Explore

White Paper

2. Bridge Design

This paper reports on a non-linear analysis of a bridge supported on sliding bearings with elastomeric restoring spring and viscous dampers. Results were verified with shake table tests.

Read More »
Case Study

10. Investigation of Light Pole Base Integrity – Rich Stadium

Light poles at Rich Stadium in Orchard Park, N.Y., were showing incipient failure of their hold-down bolts, due to wind excitation. This paper describes the measures used to alleviate this problem, including the addition of viscous dampers between the stadium structure and a point around one third up on the light poles.

Read More »

Thank You!

A Taylor Devices Representative will be in touch shortly.