96. ROOF ISOLATION SYSTEM TO REDUCE SEISMIC RESPONSE OF BUILDINGS

A roof isolation system is proposed as a means to reduce the detrimental effect of earthquakes in buildings. This roof isolation system entails the insertion of flexible laminated rubber bearings between a building's roof and the columns that support it and the addition of viscous dampers connected between the roof and the rest of the building. The properties and dimensions of the rubber bearings and viscous dampers are selected in a way that makes the roof, bearings, and dampers form a highly damped vibration absorber. Presented also is a comparative study with a simple five story steel building under a strong earthquake ground motion that is carried out to assess the effectiveness of the proposed system. In this comparative study, it is found that the roof isolation scheme reduces the floor displacements and interstory drifts of the analyzed building by as much as 83 percent. On the basis of these results and in view of its simplicity, it is concluded that the proposed roof isolation system has the potential to become a practical and effective way to reduce earthquake damage in buildings.

Share This Post

More To Explore

White Paper

12. PASSIVE AND ACTIVE FLUID DAMPERS IN STRUCTURAL APPLICATIONS

Analytical and experimental results demonstrate that the performance improvements from active control systems can also be achieved with passive and semi-active fluid dampers. However, passive or semi-active fluid dampers offer the advantages of low cost, no or minimal demand for external power, longevity and reliability.

Read More »
White Paper

15. REDUCTION OF SHOCK RESPONSE SPECTRA USING VARIOUS TYPES OF SHOCK ISOLATION MOUNTS

This experiment demonstrated how various types of shock absorbers can reduce the overall shock response spectra of a structure subjected to high impact shock. This was accomplished by measuring the acceleration on a weight dropped onto three different shock absorbers from various heights and analyzing the resulting data. A baseline test was performed with a steel hard mount. This was followed by tests with three different soft isolation mounts; a half inch thick neoprene pad, a urethane rubber tube on its side and a hydraulic liquid spring type shock absorber. Results show that both the dominant frequencies and the peak acceleration get lower as the isolation system gets softer. This information can be valuable in the design of isolation systems.

Read More »
Case Study

16. ROCKWELL VISCOUS DAMPER SPECIFICATIONS

This specification covers the set of ten linear fluid viscous dampers along with their mounting brackets and pins for the Rockwell Building located at Jamboree Road and Birch in Newport Beach, California. These dampers provide an output force in either tension of compression that is directly proportional to the relative velocity between the two ends of the dampers. The damper output force varies only with velocity and does not change with damper stroke position or orientation angle. The function of the dampers is to absorb earthquake energy, thereby reducing the amount the building moves when an earthquake occurs.

Read More »

Investor Information

2022 Q1 Important Links

 

Investor Information

2021 Q4 Important Links

Investor Information

2021 Q3 Important Links

Investor Information

2021 Q2 Important Links

Investor Information

2021 Q1 Important Links

Investor Information

2020 Q4 Important Links

Investor Information

2020 Q3 Important Links

Thank You!

A Taylor Devices Representative will be in touch shortly.

Investor Information

2020 Q1 Important Links

Investor Information

2019 Q4 Important Links